Logix ICF Logo

How to Quickly Pivot to an ICF Foundation From Conventionally Designed House Plans

Print
Email
There are plenty of reasons to change your conventional foundation house plans to an ICF design — ease of construction, energy efficiency, and elevated comfort, just to name a few. Read this article to see how relatively straightforward it is to convert your conventionally designed foundation to ICF.

There are plenty of reasons to change your conventional foundation house plans to an ICF design — ease of construction, energy efficiency, and elevated comfort, just to name a few. But did you know that it’s also relatively straightforward to convert your conventionally designed foundation to ICF?

That said, there are a number of design and construction considerations that you should consider as you convert to an ICF foundation. Here they are:

Factors to Consider When Pivoting From Conventional to a Logix ICF Basement

Footings

You shouldn’t have much trouble here.

If you have stepped footings — which are typically 24 inches high — you can opt for 2 courses of the Logix V12 blocks. Or, you can use our regular 16-inch high Logix Pro blocks and go with 16-inch steps.

Logix ICF Footings
Logix ICF Footings

Foundation Walls — Plan For A Greater Logix ICF Wall Thickness

First and foremost, your walls will be thicker if you convert to ICF; how much thicker depends on the concrete core you choose. For example, a 6.25-inch core Logix ICF block adds 3 ¾ inches to the thickness of a conventionally designed foundation wall, whereas the 8-inch core makes the wall 5.5 inches thicker (but bear in mind you will avoid all the interior framing you would otherwise have needed with the conventional walls) .

With thicker walls in mind, the easiest option is to situate the ICF’s outside face precisely where the originally designed concrete wall would’ve been.

This way, there’s no change to the building footprint or the floor area of the main floor above, BUT the basement living area becomes a bit less spacious. So, you should only consider this option if the decreased basement area doesn’t create conflict for interior elements, like washroom dimensions or stairway clearances. (Such design conflicts are more common when you’re converting a design with a completed interior plan). 

Alternatively, you can leave the basement living area as is, and instead expand the building footprint. Of course, this approach entails changes to the perimeter of exterior walls and the roof design, so you’ll incur some additional design expenses.

Optimal Foundation Wall Height

The optimal foundation wall height with Logix ICF blocks is 9 feet 4 inches. If you stick to this height, you’ll avoid field-cutting the blocks — a time-consuming and wasteful process.

That said, you can hit any height in 4-inch increments by using a combination of Logix V-12 and Pro blocks, so 9’4″ isn’t really a limitation. Just beware that if you must alter your design wall height to accommodate ICF construction, you’ll need to account for it at the excavation stage. Fortunately, though, most building departments won’t give you a hard time about this during permitting. 

Do you have a set of conventional house plans and want to pivot quickly to a Logix ICF foundation?

Watch this informative webcast recording to learn how to efficiently execute them in order to pivot to Logix ICF construction.

Don't miss a thing!

Subscribe for the latest in the ICF world, exclusive content, insider industry news and limited edition webcasts.

Rebar Specification and Engineering

Logix has a Prescriptive Engineering manual for most residential foundations — a resource that will help you tweak your rebar calculations when you convert your design to ICF. And while site-specific engineering isn’t typically required, your rebar schedule will have to comply with local codes’ seismic and wind provisions and factor in the site’s soil density.

Taper Top Blocks at the Top Course

Logix has taper-top blocks that are specially designed for the top course of a foundation wall. These blocks offer an additional concrete bearing surface for the wall assembly above and are mandatory when the brick veneer is used on the exterior (and recommended in all cases).

Logix ICF Taper Top Block

Construction Phase Considerations

Now that your design has been optimized for ICF, you’ll still need to keep some things in mind during construction. Here they are:

  • The garage slab must be sloped to the sewer to allow drainage. Keep this in mind during excavation, as your wall heights have likely changed from the conventional design.
  • The ICF sill plate will add 1 ⅝ inches to the foundation wall height. Your building official won’t mind, but do let your builder know to make the appropriate adjustments on site.
  • Waterproofing is not optional on ICF walls. You can use either peel-and-stick, dimple board, or both, but don’t skip this step.
  • You’ll have to cover up the transition strip between the ICF foundation wall and the exterior veneer above. Most often, this is done by parging, but you can also use metal siding or faux stone.
  • You’ll need an ignition barrier on the inside face of the ICF foundation wall to qualify for a Certificate of Occupancy. You can accomplish this by either simply screwing a sheet of gypsum wallboard to the wall and leaving it as is or fully taping and finishing the drywall.

Streamline Permitting — How to Submit Your Converted Plans to the Building Department

Option 1 — Submit Your Original Plans With An Addendum

Here’s how to prepare your submittal:

  1. Download the ICF foundation wall section from the Technical Library on the Logix website.
  2. Download the appropriate rebar engineering specifications from the Logix Technical Library.
  3. Attach these documents to the original plan set and label them as “Alternative ICF Foundation Option.”

Option 2 — Submit A Redesigned Plan Set

The redesign shouldn’t involve much effort or extra expense if it’s a simple enough structure — like a single-family residential building with a straightforward footprint.

On the other hand, more complex buildings may require more tedious — and expensive — redesign work to accommodate the change from conventional to ICF basement.

Just bear in mind that if you already have your building permit, when you submit these changes, with either option you’re essentially submitting a brand-new permit application.

Wrapping It Up

Bottom line – it’s really not that difficult to pivot your conventional basement design to an ICF design as long as you follow the simple steps above!

Share Post

Facebook
Twitter
LinkedIn
Pinterest

Save for Later

Email
Print
Logix Brands Editorial

Logix Brands Editorial

Delivering the latest in the ICF world, exclusive content, insider industry news, tips and insights into building better with Logix ICF. 

Subscribe To Our Newsletter

No spam, notifications only about new products, updates.

Most Recent

More For You

Get a Free Quote

Whether you’re an experienced ICF installer or considering ICF for the first time, we can help. Simply complete this short form for a free quote (or to ask any question at all!).

By submitting the form, you agree to our Terms and Conditions and our Privacy Policy. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Contact This ICF-Experienced Professional

By submitting the form, you agree to our Terms and Conditions and our Privacy Policy. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Contact This ICF-Experienced Professional

Contact Information

By submitting the form, you agree to our Terms and Conditions and our Privacy Policy. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Contact Dealer

Contact Information

By submitting the form, you agree to our Terms and Conditions and our Privacy Policy. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Projects

Building Soon

Whether you’re an experienced ICF installer or considering ICF for the first time, we can help. Simply complete this short form for a free quote (or to ask any question at all!).

By submitting the form, you agree to our Terms and Conditions and our Privacy Policy. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

General/Technical Inquiry

Whether you’re an experienced ICF installer or considering ICF for the first time, we can help. Simply complete this short form for any general or technical questions.

By submitting the form, you agree to our Terms and Conditions and our Privacy Policy. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Almost there...

For unlimited access to all of our technical and marketing resources, please enter your information. We will also email you a copy of each of the items you select for quick future reference.

By submitting the form, you agree to our Terms and Conditions and our Privacy Policy. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Logix Brands Logo

Don’t Miss a Thing!